Product Code : VF--DCCC-DC41-CU
Product structure: Direct action
Nominal diameter: DN15 - DN500
Nominal pressure: 1.6 Mpa
Working pressure difference: 0 - 0.05 Mpa
Working medium: Gas, natural gas, liquefied petroleum gas, etc. (non-corrosive gases and liquids) Closing time: < 1 second
Medium temperature: -15℃ to 60℃
Operation mode: Manual reset or electric reset
Power supply voltage: AC 220VA, DC 24V, DC 12V
Safety level: Ordinary type Ex type
Control method: Continuous output or pulsed electromagnetic force
Please contact us if you need customized services. We will contact you with the price and availability in 24 hours.
| Product | Product Code | Purity | Size | Contact Us |
The new safety accessories for gas pipeline projects are mainly applied as follows:
Connected to the combustible gas leakage monitoring instrument. When the instrument detects a gas leak, it will automatically and quickly close the main gas supply valve, cutting off the gas supply and promptly preventing the occurrence of a serious accident.
2. Connected to the safety controller for the maximum temperature (or pressure) of the thermal equipment. When the detected temperature or pressure within the equipment exceeds the set limit value, the gas supply valve will automatically and rapidly close, stopping the supply of fuel.
3. Connected to the central fire alarm system of the high-rise building. In case of an emergency in the building, the gas supply within the building will be automatically cut off to prevent the occurrence of a gas explosion.
4. Install ZCR gas emergency shut-off valves within the gas supply networks of cities or factories. Central control is implemented in the control room, with remote remote control capabilities. In case of an emergency, these valves can be used to shut off the gas supply to the accident site from a distance.
The new safety accessories for gas pipeline projects are mainly applied as follows:
Connected to the combustible gas leakage monitoring instrument. When the instrument detects a gas leak, it will automatically and quickly close the main gas supply valve, cutting off the gas supply and promptly preventing the occurrence of a serious accident.
2. Connected to the safety controller for the maximum temperature (or pressure) of the thermal equipment. When the detected temperature or pressure within the equipment exceeds the set limit value, the gas supply valve will automatically and rapidly close, stopping the supply of fuel.
3. Connected to the central fire alarm system of the high-rise building. In case of an emergency in the building, the gas supply within the building will be automatically cut off to prevent the occurrence of a gas explosion.
4. Install ZCR gas emergency shut-off valves within the gas supply networks of cities or factories. Central control is implemented in the control room, with remote remote control capabilities. In case of an emergency, these valves can be used to shut off the gas supply to the accident site from a distance.
Packing of Standard Packing:
Typical bulk packaging includes palletized plastic 5 gallon/25 kg. pails, fiber and steel drums to 1 ton super sacks in full container (FCL) or truck load (T/L) quantities. Research and sample quantities and hygroscopic, oxidizing or other air sensitive materials may be packaged under argon or vacuum. Solutions are packaged in polypropylene, plastic or glass jars up to palletized 470 gallon liquid totes Special package is available on request. E FORUs’ is carefully handled to minimize damage during storage and transportation and to preserve the quality of our products in their original condition.